A moisture test report is a record of conditions at defined spots on a slab at a defined time. Owners, GCs, flooring contractors and product representatives all use it to make decisions, so it has to stand on its own: someone who was not on site should be able to tell what was tested, how, when and under what conditions.
The parts of a complete report
- Project identification
- Address, building or unit, area tested, who requested it, and who performed it.
- Method and edition
- Which standard was followed (for example ASTM F2170 or F1869) and which edition, plus any deviations.
- Locations
- Each test point marked on a plan, with enough description to find it again.
- Dates and times
- When holes were drilled or domes placed, and when each reading was taken.
- Slab details
- Thickness where known, depth of probe holes, surface condition and any coatings or residue found.
- Site conditions
- Ambient temperature and humidity, HVAC status and anything unusual during the test window.
- Readings
- The result for every location, in the units of the method used, not just an average.
- Equipment
- The instruments used and their calibration status, as the method requires.
- Limitations
- A plain statement that results apply to the tested locations and time.
- Comparison reference
- The product limits supplied for comparison, identified by product and document.
Example layout
The table below shows how a results section is often organized. It is a layout example only: it contains no readings.
| Location | Placed | Read | Result (method units) | Ambient at reading |
|---|---|---|---|---|
| Location 1 (plan ref.) | date / time | date / time | — | temp / RH |
| Location 2 (plan ref.) | date / time | date / time | — | temp / RH |
| Location 3 (plan ref.) | date / time | date / time | — | temp / RH |
Questions to ask when a report lands
- Does the method match the instructions? A limit written for in-situ RH does not apply to a calcium chloride result, and the reverse.
- Were there enough tests, in the right places? Check the count against the method and the spec, and that the locations cover the areas being floored.
- Was the building at service conditions? Look for the recorded temperature, humidity and HVAC status.
- Is every reading shown? One high location matters even if the average looks fine.
- How old is it? A report describes the time of testing. If weeks have passed or conditions have changed, ask whether retesting makes sense.
Planning the site visit? Use the testing-day checklist.